<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-03 04-48-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 50 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.7 kHz -83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19139 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,3 dBr 4,38 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2026/05/03 4.47.18 Total samples: 19139 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 5,7 dBr MIN: 1,3 dBr AVE: 4,38 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2026/05/03 4.47.18) 04.34 04.36 04.38 04.40 04.42 04.44 04.46 0 2 4 6 Pm [dBr]